PZH R1 275/12,5/3+1 MS

Code: 7716094

PZH R1 275/12,5/3+1 MS

Code: 7716094

PZH R1*M is a lightning and surge arrester according to EN 61643-11 ed.2 (IEC 61643-11:2011) consisting of high energy varistors in combination with gas discharge tube, which ensures zero leakage current in the PE conductor. Its parameters enable usage in buildings with considerable levels of protection LPL III and LPL IV, such as small administration complexes, residential buildings, family houses or properties and halls without the incidence of persons and indoor equipment. The device is to be installed on the interface of LPZ 0 – LPZ 1 and higher zones according to standard EN 62305 ed.2 (IEC 62305:2010), closest to where overhead line enters the building i.e. in the main distribution boards. S indication specifies a version with remote monitoring. M indication specifies a type of construction with removable module.
Gewicht: 0.54

TECHNISCHE DATEN UND NORMEN

IM KATALOG VERWENDETE KENNZEICHNUNGEN

MATERIALIEN


KENNZEICHNUNG
MATERIAL
Rf
rostfreier Stahl
Rf*H4
säurebeständiger Edelstahl
Cu
Kupfer
Al
Aluminium
Fe
Stahl
FeZn
verzinkter Stahl
FeZn-H
feuerverzinkter Stahl
KFe
gehärteter Stahl
FeCu
verkupferter Stahl
Me
Messing
PE
Polyethylen – UV-stabil
N
Nylon – UV-stabil
P-SV
UV-verstärkter Polyester
pvc
elektrostatisch plastifiziert
PVC
widerstandsfähiger Kunststoff
Holz
Holz
Beton
Beton
Gus
Gusseisen
CuSn
verzinntes Kupfer
PP
Polypropylen

ABMESSUNGEN DES LEITERS

(Eignung der Träger für ein bestimmtes Leiterprofil)

KENNZEICHNUNG
BEDEUTUNG
Φ

Durchmesser des Rundleiters

P

Querschnittsabmessungen des Flachleiters


DRAHTKONDITIONSSYSTEM UND HALTERUNG

KENNZEICHNUNG
BEDEUTUNG
N

Befestigung mit Nylonverschluss

PE

Befestigung mit Polyäthylenverschluss

K
Befestigung mit Klicksystem
V
Befestigung durch Schrauben
*
benutzerdefiniert
Legende der Symbole
PZH R1*M is a lightning and surge arrester according to EN 61643-11 ed.2 (IEC 61643-11:2011) consisting of high energy varistors in combination with gas discharge tube, which ensures zero leakage current in the PE conductor. Its parameters enable usage in buildings with considerable levels of protection LPL III and LPL IV, such as small administration complexes, residential buildings, family houses or properties and halls without the incidence of persons and indoor equipment. The device is to be installed on the interface of LPZ 0 – LPZ 1 and higher zones according to standard EN 62305 ed.2 (IEC 62305:2010), closest to where overhead line enters the building i.e. in the main distribution boards. S indication specifies a version with remote monitoring. M indication specifies a type of construction with removable module.
ISO9001_&_ISO14001_de.pdf
Name der Webseite

Kontakt

Hermi GmbH

Gabelsbergerstraße 5

9020 Klagenfurt am Wörthersee

Österreich


+43 664 192 33 69

verkauf@hermi.at